Auto Power Off
Period
 |
Selects the auto off time period
in minutes:
"Off" = Disabled (Always On)
 |
Hold Mode
Enable
 |
Activates the "Hold: mode where weight
of the object on the platform is frozen on the display until the applied
weight is decreased to one half of the memorized weight. This is used in
conjunction with the Motion Band setting to capture an unstable load,
such as livestock
 |
Motion Band
 |
Sets the level at which motion is
detected by comparing the present display update with the previous one.
If motion is not detected for two seconds or more, scale is in
standstill and can process a Print or Zero command. Maximum value varies
depending on local regulations
 |
Digital Filter |
Averages weight readings to produce
higher stability. The higher the filter setting, the greater the
stability but the slower the indicator’s response time.
 |
Internal Resolution Approximately 130,000 counts
Excitation Voltage +5VDC, 4 x350W load cells
Alkaline Batteries 6 – "C" Size Cells
Rechargeable Battery 6 VDC, 3.0 Ah lead acid
AC Adapter – Alkaline Batteries 12 VDC, 500mA Female
AC Adapter – Rechargeable Battery 12 VDC, 800mA Female
Power Consumption _ TI-500BW 80mA + 30mA per 350W Loadcell
MECHANICAL
Overall Dimensions – Plastic 8.1" x 11.8" x 3.9" (205mm x
300mm x 100mm)
*Massload has developed optional software to work with this
indicator. Connect this indicator to your computer and save your data. Ask us
about this software. |